How to resolve fault F1214 with the name fltBgpPeerEntryOperStShut

Cisco System Model: Fault fltBgpPeerEntryOperStShut

Cisco System Model: Class ifc:eventmgr:fltBgpPeerEntryOperStShut

This pages provides an overview over ACI Fault: F1214

Explanation: This fault occurs when the peer is shut down because the prefix limit is exceeded or no memory
Recommended Action: To recover from this fault, try the following actions Look at any configuration issues Verify the configuration is correct/complete Reduce the number of prefixes exported into bgp If the above actions did not resolve the issue, generate the show tech-support file and contact Cisco TAC.

Raised on MO: bgp:PeerEntry
Fault Name: fltBgpPeerEntryOperStShut

Unqualified API Name: operStShut

Code: F1214
Applied Mo DN Format

  • topology/pod-[id]/node-[id]/sys/bgp/inst/dom-[name]/peer-[addr]/ent-[addr]
  • sys/bgp/inst/dom-[name]/peer-[addr]/ent-[addr]

Type: operational
Cause: protocol-bgp-adjacency-down
Severity: warning
Weight: 100
Tags:
Message: None
Help: None
Triggered By: operSt equals shut and shutStQual equals no-mem or shutStQual equals exceeded-pfxlimit